FingerTec Ingressus i, ii, iv
Security Hub for Smart Controller
The Ingressus series controller supports access control for a
1-door (Ingressus I),
2-doors (Ingressus II)
4-doors (Ingressus IV)
environment. Users verify their identities at the relevant Wiegand terminals or RS485 readers
by fingerprint, card, password or any combination during entry and exit.
The Ingressus controllers verify users’ identities before granting them access.
Transaction records are saved into its inbuilt memory and the records are sent to the software immediately for further processing.
Once multiple Ingressus controllers are set up, they can be centralized via IP or RS485 connection in a computer installed with the
bundled Ingress software. Each Ingressus controller works independently at its access point; however the data is centralized from
all Ingressus controllers to give a better and complete picture of the environment’s security level.
Ingress is an integrated access control management application designed exclusively for FingerTec devices.
It runs on the common MS Windows operating environment and the software is a complete solution for centralizing, managing,
and monitoring door activities of all FingerTec devices. Bundled with the Ingressus Controller, Ingress is an advanced, easy to use,
and IT-friendly software that provides comprehensive access control features such as real-time monitoring,
database administration and report management, all within a single unified system.
Ideally suited for self-managed organizations of below 100-door environment,
Ingress is also capable of seamlessly integrating its access control functions with
alarm monitoring as well as other intrusion detection devices.
This product also presents a complete and useful time attendance features to track staff’s
attendance in addition to simplifying the complex scheduling module for all users.
Ingress supports all standalone FingerTec access control models that use card, fingerprint and face recognition verification.
Additionally, multiple terminals can be centralized in the Ingressus Network Control Panel for multiple-door monitoring.
Centralised Storage
Capacity Made For Security Devices
Transactions : 100,000
Fingerprints : 3,000
MODEL |
Ingressus I |
Ingressus II |
Ingressus IV |
Terminals |
2 |
4 |
4 |
Inputs |
1 |
2 |
4 |
Outputs |
1 |
2 |
4 |
MODEL |
Ingressus I |
Ingressus II |
Ingressus IV |
BASIC |
|
|
Dimension |
186 x 106 x 36 |
226 x 106 x 36 |
(L X W X H), mm |
Power input |
12V DC |
Operating temperature (°C) |
0 - 55 |
Operating humidity (%) |
Oct-80 |
CPU |
32-bit, 400MHz |
Flash memory (MB) |
128 |
SDRAM (MB) |
32 |
Polarity protection |
Yes |
STORAGE |
|
Fingerprints |
3,000 |
Passwords |
30,000 |
Transactions |
100,000 |
COMMUNICATIONS |
|
|
|
Communications with server |
TCP/IP |
Quantity of terminal |
2 |
4 |
4 |
Communication with terminals |
2 x 26-bit Wiegand input. |
4 x 26-bit Wiegand input. |
4 x 26-bit Wiegand input. |
Each for 1 slave terminal (1 x RS485 input to support RS485 network) |
Each for 1 slave terminal (1 x RS485 input to support RS 485 network) |
Each for 1 slave terminal (1 x RS485 input to support RS 485 network) |
(max 2 units) |
(max 4) |
(max 8 units) |
INPUT |
|
|
|
Push release button |
1 |
2 |
4 |
Door sensor |
1 |
2 |
4 |
AUX |
1 |
2 |
4 |
Types of AUX input supported |
Motion detector, passive DIR detector, curtain passive infrared detector, pet immunity PIR detector, two beams digital active infrared detector, heat detector |
OUTPUT |
|
|
|
Door lock (12VDC 10A form C relay) |
1 |
2 |
4 |
AUX output (30VDC 2A form C relay) |
1 |
2 |
4 |
Types of AUX output supported |
Gas detector and compatible sensors, Piezo strobe siren, electronic siren |
ACCESS CONTROL FEATURES |
|
|
|
Main Features |
Door opening time (0-999s), inter-locking (lngressus II & IV only), anti-passback (Local only), time zone (50), holiday time zone, permanent door release/ lock time zone, daylight saving time zone, continuous verification of users |
Security Features |
Door forced open alarm, door open time out alarm, fire linkage, duress alarm, door status and event (51 types) |