| Models |
2.5K |
3K |
3.6K |
4K |
4.6K |
5K |
6K |
| Input DC |
| Recommended max. PV power |
3.75 kW |
4.5 kW |
5.4 kW |
6 kW |
6.9 kW |
7.5 kW |
9 kW |
| Max. Input Voltage |
550V |
| Rated Voltage |
250V |
330V |
| Start-up Voltage |
60V |
100V |
| MPPT Voltage Range |
50-550V |
90-550V |
| Max. Input Current |
16A/16A |
| Max. Short Circuit Current |
22A/22A |
| MPPT Number/Max. Input Strings Number |
2/2 |
| Output Data (AC) |
| Rated Output Power |
2.5 kW |
3 kW |
3.6 kW |
4 kW |
4.6 kW |
5 kW |
6 kW |
| Max. Apparent Output Power |
2.5 kVA |
3 kVA |
3.6 kVA |
4 kVA |
4.6 kVA |
5 kWA |
6 kVA |
| Max. Output Power |
2.5 kW |
3 kW |
3.6 kW |
4 kW |
4.6 kW |
5 kW |
6 kW |
| Rated Grid Voltage |
1/N/PE, 220V/230V |
| Rated Grid Frequency |
50 Hz / 60 Hz |
| Rated Grid Output Current |
11.4A/10.9A |
13.6 A / 13 A |
16 A / 15.7 A |
18.2 A / 17.4 A |
20.9 A / 20 A |
22.7 A / 21.7 A |
27.3 A / 26.1 A |
| Maximum Output Current |
11.4 A / 10.9 A |
13.6 A / 13 A |
16 A / 15.7 A |
18.2 A / 17.4 A |
20.9 A / 20 A |
22.7 A / 21.7 A |
27.3 A / 26.1 A |
| Maximum Output Current |
11.4 A |
13.6 A |
16 A |
18.2 A |
20.9 A |
22.7 A |
27.3 A |
| Power Factor |
>0.99 (0.8 leading - 0.8 lagging) |
| THDi |
<3% |
| Efficiency |
| Max. efficiency |
97.3% |
97.3% |
97.6% |
97.7% |
| Night Power Consumption |
96.5% |
96.6% |
97.1% |
97.1% |
| Protection |
| DC reverse-polarity protection |
Yes |
| Short circuit protection |
Yes |
| Output over current protection |
Yes |
| Surge protection |
Yes |
| Grid monitoring |
Yes |
| Anti-islanding protection |
Yes |
| Temperature protection |
Yes |
| Integrated AFCI 2.0 |
Optional |
| Integrated DC Switch |
Yes |
| General Data |
| Dimensions (W*H*D) |
330*371*161 mm |
| Weight |
8.2kg |
8.3kg |
8.9kg |
9kg |
| Topology |
Transformerless |
| Self-consumption (night) |
<1 W |
| Operating ambient temperature range |
-25 ~ +60°C |
| Relative humidity |
0-100% |
| Ingress protection |
IP66 |
| Noise emission (typical) |
<20 dB(A) |
| Cooling concept |
Natural convection |
| Max. operation altitude |
4000m |
| Grid connection standard |
G98 or G99, VDE-AR-N 4105 / VDE V 0124, EN 50549-1, VDE 0126 / UTE C 15 / VFR:2019, RD 1699 / RD 244 / UNE 206006 / UNE 206007-1, CEI 0-21, C10/11, NRS 097-2-1, EIFS 2018.2, IEC 62116, IEC 61727, IEC60068, IEC 61683, EN 50530, MEA, PEA |
| Safety/EMC standard |
IEC/EN 62109-1/-2, IEC/EN 61000-6-2/-3 |
| Features |
| DC connection |
MC4 connector |
| AC connection |
Quick connection plug |
| Display |
LED + APP |
| Communication |
RS485, USB, Optional: Wi-Fi, GPRS |