Console ports
|
RJ-45 Ethernet
|
1
|
1
|
1
|
1
|
USB-A port for storage and Bluetooth console
|
1
|
1
|
1
|
1
|
Memory and processor
|
CPU
|
ARM v7 800 MHz
|
ARM v7 800 MHz
|
ARM v7 800 MHz
|
ARM v7 800 MHz
|
DRAM
|
512 MB
|
512 MB
|
512 MB
|
512 MB
|
Flash memory
|
256 MB
|
256 MB
|
256 MB
|
256 MB
|
Performance
|
Forwarding bandwidth
|
10 Gbps
|
18 Gbps
|
FE: 6.4 Gbps
1G: 28 Gbps
10G: 64 Gbps
|
FE: 8.8 Gbps
1G: 52 Gbps
10G: 88Gpbs
|
Switching bandwidth
|
20 Gbps
|
36 Gbps
|
FE: 12.8 Gbps
1G: 56 Gbps
10G: 128 Gbps
|
FE: 17.6 Gbps
1G: 104 Gbps
10G: 176 Gbps
|
Forwarding rate
(64 byte L3 packets)
|
14.88 Mpps
|
26.78 Mpps
|
FE: 9.52 Mpps
1G: 41.67 Mpps
10G: 95.23 Mpps
|
FE: 13.09 Mpps
1G: 77.38 Mpps
10G: 130.94
|
Unicast MAC addresses
|
16000
|
16000
|
16000
|
16000
|
IPv4 unicast direct routes
|
542
|
542
|
542
|
542
|
IPv4 unicast indirect routes
|
256
|
256
|
256
|
256
|
IPv6 unicast direct routes
|
414
|
414
|
414
|
414
|
IPv6 unicast indirect routes
|
128
|
128
|
128
|
128
|
IPv4 multicast routes and IGMP groups
|
1024
|
1024
|
1024
|
1024
|
IPv6 multicast groups
|
1024
|
1024
|
1024
|
1024
|
IPv4/MAC security ACEs
|
600
|
600
|
600 (FE: 384)
|
600 (FE: 384)
|
IPv6 security ACEs
|
600
|
600
|
600 (FE: 256)
|
600 (FE: 256)
|
Maximum active VLANs
|
256
|
256
|
256
|
256
|
VLAN IDs available
|
4094
|
4094
|
4094
|
4094
|
Maximum STP instances
|
64
|
64
|
64
|
64
|
Maximum SPAN sessions
|
4
|
4
|
4
|
4
|
MTU-L3 packet
|
9198 bytes
|
9198 bytes
|
9198 bytes
|
9198 bytes
|
Jumbo Ethernet frame
|
10,240 bytes
|
10,240 bytes
|
10,240 bytes
|
10,240 bytes
|
Dying Gasp
|
Yes
|
Yes
|
Yes (FE: No)
|
Yes (FE: No)
|
MTBF in hours (data)
|
2,171,669
|
2,165,105
|
2,026,793
|
1,452,667
|
MTBF in hours (PoE)
|
1,786,412, 1,706,649 (External PS)
|
706,983
|
698,220
|
856,329
|
MTBF in hours (Full PoE)
|
1,706,649
|
-
|
698,220
|
856,329
|
Environmental
|
Operating temperature
|
Sea level
|
-5 to 50 deg C*
|
Up to 5,000ft (1500 m)
|
-5 to 45 deg C
|
Upto 10,000 (3000 m)
|
-5 to 40 deg C
|
Operating altitude
|
10,000 ft (3,000m)
|
Operating relative humidity
|
5% to 90% at 40 deg C (non-condensing)
|
Storage temperature
|
-13 to 158F (-25 to 70C)
|
Storage altitude
|
15,000 ft (4500m)
|
Storage relative humidit
|
5% to 95% at 65 deg C (non-condensing)
|
*Note:
|
¡ñ 50C operation is supported for short term operation only;
¡ñ When using C1000-8T-E-2G-L, C1000-8T-2G-L, C1000-8P-E-2G-L, C1000-8P-2G-L, C1000-8FP-E-2G-L, C1000-8FP-2G-L, C1000-16T-E-2G-L, C1000-16T-2G-L, C1000-16P-E-2G-L, C1000-16P-2G-L, C1000-16FP-2G-L, C1000-24T-4G-L, C1000-24P-4G-L with GLC-BX-U or GLC-BX-D SFP module, the thermal limitations are as follows:
%æ Up to 5,000 feet, the operation temperature should not exceed 45ºC.
%æ Up to 10,000 feet, the operation temperature should not exceed 40ºC.
¡ñ When using C1000-24T-4X-L, C1000-24P-4X-L with SFP-10G-ER or SFP-10G-ER-S SFP+ module, the thermal limitations are as follows:
%æ Up to 5,000 feet, the operation temperature should not exceed 45ºC.
%æ Up to 10,000 feet, the operation temperature should not exceed 40ºC.
¡ñ Minimum ambient temperature for cold start is at 0 deg C (32 deg F) |
Electrical
|
Data
|
Data Ext.PS
|
Data
|
Data Ext. PS
|
Data
|
FE Data
|
Data
|
FE Data
|
Voltage
(auto ranging)
|
110 to 220V AC in
|
110 to 220V AC in
|
110 to 220V AC in
|
110 to 220V AC in
|
Frequency
|
50 to 60 Hz
|
50 to 60 Hz
|
50 to 60 Hz
|
50 to 60 Hz
|
Current
|
0.13A to 0.22A
|
0.16A to 0.26A
|
0.16A to 0.26A
|
0.19A to 0.31A
|
0.20A to 0.33A
|
0.12A to 0.34A
|
0.29A to 0.48A
|
0.24A to 0.69A
|
Power rating
(maximum consumption)
|
0.04 kVA
|
0.017 kVA
|
0.05 kVA
|
0.05 kVA
|
0.06 kVA
|
0.02 kVA
|
0.09 kVA
|
0.035 kVA
|
Electrical
|
PoE
|
PoE Ext. PS
|
PoE
|
PoE Ext. PS
|
PoE
|
FE PoE
|
PoE
|
FE PoE
|
Voltage
(auto ranging)
|
110 to 220V AC in
|
110 to 220V AC in
|
110 to 220V AC in
|
110 to 220V AC in
|
Frequency
|
50 to 60 Hz
|
50 to 60 Hz
|
50 to 60 Hz
|
50 to 60 Hz
|
Current
|
0.22A to 0.27A
|
0.22A to 0.37A
|
0.24A to 0.28A
|
0.14A to 0.24A
|
0.37A to 0.64A
|
0.23A to 0.35A
|
0.37A to 0.64A
|
0.26A to 0.46A
|
Power rating
(maximum consumption)
|
0.11 kVA
|
0.087 kVA
|
0.19 kVA
|
0.20 kVA
|
0.48 kVA
|
0.025 kVA
|
0.48 kVA
|
0.046 kVA
|
Electrical
|
Full PoE
|
Full PoE Ext. PS
|
Full PoE
|
Full PoE
|
Full PoE
|
Voltage (auto ranging)
|
110 to 220V AC in
|
110 to 220V AC in
|
110 to 220V AC in
|
110 to 220V AC in
|
Frequency
|
50 to 60 Hz
|
50 to 60 Hz
|
50 to 60 Hz
|
50 to 60 Hz
|
Current
|
0.23A to 0.28A
|
0.15A to 0.2A
|
0.35A to 0.37A
|
0.29A to 0.48A
|
0.45A to 0.94A
|
Power rating
(maximum consumption)
|
0.15 kVA
|
0.15 kVA
|
0.45 kVA
|
0.8 kVA
|
0.95 kVA
|
Power consumption (watts)
|
Data
|
Data Ext.PS
|
Data
|
Data Ext. PS
|
Data
|
FE Data
|
Data
|
FE Data
|
0% traffic
|
14.04
|
13.15
|
14.52
|
14.4
|
1G: 15.84
|
11.22
|
1G: 27.37
|
21.41
|
|
|
|
|
10G: 18
|
|
10G: 29.4
|
|
10% traffic
|
14.06
|
13.76
|
16.44
|
16.44
|
1G: 22.08
|
12.83
|
1G: 41.57
|
23.02
|
|
|
|
|
10G: 24.48
|
|
10G: 42.28
|
|
100% traffic
|
14.26
|
14
|
16.68
|
16.68
|
1G: 22.8
|
17.15
|
1G: 53.66
|
23.03
|
|
|
|
|
10G: 25.68
|
|
10G: 54.73
|
|
Weighted average
|
14.12
|
13.64
|
15.88
|
15.84
|
1G: 20.2
|
13.73
|
1G: 40.87
|
22.49
|
|
|
|
|
10G: 22.7
|
|
10G: 42.1
|
|
Power consumption (watts)
|
PoE
|
PoE Ext. PS
|
PoE
|
PoE Ext. PS
|
PoE
|
FE PoE
|
PoE
|
FE PoE
|
0% traffic
|
10.22
|
9.13
|
14.64
|
13.68
|
1G: 15.84
|
14.5
|
1G: 27.9
|
21.62
|
|
|
|
|
10G: 18
|
|
10G: 28.0
|
|
10% traffic
|
12.02
|
15.39
|
16.56
|
15.48
|
1G: 22.44
|
16.1
|
1G: 42.77
|
24.74
|
|
|
|
|
10G: 24.72
|
|
10G: 42.73
|
|
100% traffic
|
12.19
|
15.71
|
16.92
|
16.32
|
1G: 23.16
|
18.58
|
1G: 54.25
|
24.75
|
|
|
|
|
10G: 25.68
|
|
10G: 54.49
|
|
Weighted average
|
11.48
|
13.41
|
16.04
|
15.16
|
1G: 20.48
|
16.39
|
1G: 41.64
|
23.70
|
|
|
|
|
10G: 22.8
|
|
10G: 41.74
|
|
Power consumption (watts)
|
Full PoE
|
Full PoE Ext. PS
|
Full PoE
|
Full PoE
|
Full PoE
|
0% traffic
|
13.44
|
14.3
|
14.4
|
1G: 18.36
|
1G: 30.61
|
|
|
|
10G: 19.68
|
10G: 30.91
|
10% traffic
|
14.4
|
14.9
|
16.68
|
1G: 26.16
|
1G: 45.16
|
|
|
|
10G: 26.28
|
10G: 45.78
|
100% traffic
|
14.52
|
15.7
|
16.8
|
1G: 35.4
|
1G: 61.66
|
|
|
|
10G: 36
|
10G: 62.26
|
Weighted average
|
14.12
|
14.97
|
15.96
|
1G: 26.68
|
1G: 45.81
|
|
|
|
10G: 27.32
|
10G: 46.31
|
Note: The wattage rating on the power supply does not represent actual power draw. It indicates the maximum power draw possible by the power supply. This rating can be used for facility capacity planning. For PoE switches, cooling requirements are smaller than total power draw because a significant portion of the load is dissipated in the endpoints.
|
Acoustic noise (48-port PoE models only)
|
Sound pressure (Typical)
|
|
|
C1000-24FP-4G-L, C1000-24FP-4X-L – 34.8 dB
|
C1000-48T-4G-L, C1000-48T-4X-L – 31.5 dB
|
|
|
|
C1000-48P-4G-L, C1000-48P-4X-L – 36.1 dB
|
|
|
|
C1000-48FP-4G-L
C1000-48FP-4X-L – 47.6dB
|
Note: Bystander positions operating mode at 77°F (25°C) ambient; All other models are fanless for silent operations
|
Safety and compliance
|
Safety
|
UL 60950-1 Second Edition, CAN/CSA-C22.2 No. 60950-1 Second Edition, EN 60950-1 Second Edition, IEC 60950-1 Second Edition, AS/NZS 60950-1, IEC 62368-1, UL 62368-1
GB 4943.1-2011
|
EMC: Emissions
|
47CFR Part 15 Class A, AS/NZS CISPR32 Class A, CISPR32 Class A, EN55032 Class A, ICES-003 Class A, VCCI-CISPR32 Class A, EN61000-3-2, EN61000-3-3, KN32 Class A, CNS13438 Class A
|
EMC: Immunity
|
EN55024 (including EN 61000-4-5), EN300386, KN35
|
Environmental
|
Reduction of Hazardous Substances (RoHS) including Directive 2011/65/EU
|
Telco
|
Common Language Equipment Identifier (CLEI) code
|
U.S. government certifications
|
USGv6 and IPv6 Ready Logo
|
Connectors and interfaces
|
Ethernet interfaces
|
10BASE-T ports: RJ-45 connectors, 2-pair Category 3, 4, or 5 Unshielded Twisted Pair (UTP) cabling
|
100BASE-TX ports: RJ-45 connectors, 2-pair Category 5 UTP cabling
|
1000BASE-T ports: RJ-45 connectors, 4-pair Category 5 UTP cabling
|
1000BASE-T SFP-based ports: RJ-45 connectors, 4-pair Category 5 UTP cabling
|
Indicator LEDs
|
Per-port status: link integrity, disabled, activity
|
System status: System
|
Console cables
|
CAB-CONSOLE-RJ45 Console cable 6 ft. with RJ-45
|
Power
|
Use the supplied AC power cord to connect the AC power connector to an AC power outlet
Models have external power supply
|
Management
|
BRIDGE-MIB
CISCO-CABLE-DIAG-MIB
CISCO-CDP-MIB
CISCO-CLUSTER-MIB
CISCO-CONFIG-COPY-MIB
CISCO-CONFIG-MAN-MIB
CISCO-DHCP-SNOOPING-MIB
CISCO-ENTITY-VENDORTYPE-OID-MIB
CISCO-ENVMON-MIB
CISCO-ERR-DISABLE-MIB
CISCO-FLASH-MIB
CISCO-FTP-CLIENT-MIB
CISCO-IGMP-FILTER-MIB
CISCO-IMAGE-MIB
CISCO-IP-STAT-MIB
CISCO-LAG-MIB
CISCO-MAC-NOTIFICATION-MIB
CISCO-MEMORY-POOL-MIB
CISCO-PAGP-MIB
CISCO-POE-EXTENSIONS-MIB
|
CISCO-PORT-QOS-MIB
CISCO-PORT-SECURITY-MIB
CISCO-PORT-STORM-CONTROL-MIB
CISCO-PRODUCTS-MIB
CISCO-PROCESS-MIB
CISCO-RTTMON-MIB
CISCO-SMI-MIB
CISCO-STP-EXTENSIONS-MIB
CISCO-SYSLOG-MIB
CISCO-TC-MIB
CICSO-TCP-MIB
CISCO-UDLDP-MIB
CISCO-VLAN-IFTABLE
CISCO-VLAN-MEMBERSHIP-MIB
CISCO-VTP-MIB
ENTITY-MIB
ETHERLIKE-MIB
IEEE8021-PAE-MIB
IEEE8023-LAG-MIB
|
IF-MIB
INET-ADDRESS-MIB
OLD-CISCO-CHASSIS-MIB
OLD-CISCO-FLASH-MIB
OLD-CISCO-INTERFACES-MIB
OLD-CISCO-IP-MIB
OLD-CISCO-SYS-MIB
OLD-CISCO-TCP-MIB
OLD-CISCO-TS-MIB
RFC1213-MIB
RMON-MIB
RMON2-MIB
SNMP-FRAMEWORK-MIB
SNMP-MPD-MIB
SNMP-NOTIFICATION-MIB
SNMP-TARGET-MIB
SNMPv2-MIB
TCP-MIB
UDP-MIB
|
For an updated list of supported MIBs, refer to the MIB Locator at cisco.com/go/mibs.
|
Standards
|
IEEE 802.1D STP
IEEE 802.1p CoS Prioritization
IEEE 802.1Q VLAN
IEEE 802.1s
IEEE 802.1w
IEEE 802.1X
IEEE 802.1ab LLDP
Bluetooth v4.0
|
IEEE 802.3ad
IEEE 802.3af and IEEE 802.3at
IEEE 802.3ah (100BASE-X single/multimode fiber only)
IEEE 802.3x full duplex on 10BASE-T, 100BASE-TX, and 1000BASE-T ports
IEEE 802.3 10BASE-T
IEEE 802.3u 100BASE-TX
|
IEEE 802.3ab 1000BASE-T
IEEE 802.3z 1000BASE-X
RMON I and II standards
SNMP v1, v2c, and v3
IEEE 802.3az
IEEE 802.3ae 10 Gigabit Ethernet
IEEE 802.1ax
|
RFC compliance
|
RFC 768 - UDP
RFC 783 - TFTP
RFC 791 - IP
RFC 792 - ICMP
RFC 793 - TCP
RFC 826 - ARP
RFC 854 - Telnet
RFC 951 - Bootstrap Protocol (BOOTP)
RFC 959 - FTP
RFC 1112 - IP Multicast and IGMP
RFC 1157 - SNMP v1
RFC 1166 - IP Addresses
|
RFC 1256 - ICMP Router Discovery
RFC 1305 - NTP
RFC 1492 - TACACS+
RFC 1493 - Bridge MIB
RFC 1542 - BOOTP extensions
RFC 1901 - SNMP v2C
RFC 1902-1907 - SNMP v2
RFC 1981 - Maximum Transmission Unit (MTU) Path Discovery IPv6
FRC 2068 - HTTP
RFC 2131 - DHCP
RFC 2138 - RADIUS
RFC 2233 - IF MIB v3
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|